123 Sample Street
Inspector
Inspector Network
inspectornetwork.com
123 Sample Street
Sample City, FL 00000
Inspected July 10, 2026
123 Sample Street
0
Safety Hazard
2
High Severity
14
Medium Severity
2
Low Severity
01.1 Inspection Details
Services Rendered Home Inspection, 4-Point Inspection, Wind Mitigation
In Attendance Client, Buyer's Agent
Methodologies used Visual, Drones, Camera Pole
Thermal Imaging Utilized
Property Access Accessible - Lockbox
Understanding Thermal Imaging
Thermal imaging technology was utilized as an additional inspection tool during the evaluation of the property...

Thermal imaging technology was utilized as an additional inspection tool during the evaluation of the property. Infrared cameras detect differences in surface temperatures that may indicate conditions warranting further investigation, such as moisture intrusion, air leakage, missing insulation, overheating electrical components, or HVAC performance concerns.

Thermal imaging does not allow the inspector to see through walls, ceilings, or other building materials, and temperature variations alone do not confirm the presence of a defect. Findings identified through thermal imaging should be considered in conjunction with visual observations and other inspection methods. Not all conditions produce detectable thermal patterns, and the absence of an observed temperature anomaly should not be interpreted as confirmation that a component is free of defects.

01.2 Utilities
Water service Active
Electric service Active
Gas service No Gas Present
Water source Municipal
Sewage system Municipal Sewer
01.3 Weather
Temperature Hot (90°F+)
Visibility Mostly Clear
Precipitation None
01.4 Property Details
Property Status Existing Home
Type of Building Single Family
Occupancy Vacant
Number of Stories 1
Animals On Location None
01.5 Site Conditions
Surface Conditions Dry
Ground Cover Grass, Bare Soil
01.6 Interior Conditions
Interior Temperature (F) 76
Interior Humidity (%) 57
HVAC Operating Mode Cooling
Thermostat Set Point (°F) 76
02.1 Grading & Drainage
Surface Grading Positive
Site Drainage Conditions Functional
Evidence of Standing Water or Ponding No
Evidence of Erosion No
02.2 Driveway
Driveway Material Concrete
Overall Driveway Condition Functional
Cracking Observed? Significant
Settlement or Displacement Observed? No
Trip Hazard Present? Yes
Driveway Slopes Toward Structure? No
Surface Spalling / Scaling? None
02.D1 High Severity
Site & Grounds
Driveway - Moderate Cracking

Cracking and vertical displacement were observed in the concrete driveway slab at the time of inspection. Displacement of approximately 1 inch was noted at affected crack locations, with heaving of the slab surface present in multiple areas. The driveway surface is not severely deteriorated overall, but the displacement and cracking represent a notable departure from acceptable condition.

A qualified concrete or flatwork contractor should be consulted to evaluate the affected sections and recommend appropriate corrective action, which may include slab grinding, mudjacking, or panel replacement.

Inspection photo Inspection photo Inspection photo
02.D2 Medium Severity
Site & Grounds
Driveway - Trip Hazard

A trip hazard was observed at the driveway surface. The condition appears consistent with displacement or settlement of the paving material, resulting in an uneven surface edge or elevation change.

Trip hazards at driveways present a safety concern for occupants and visitors. The condition may worsen over time if contributing factors continue to affect the surface.

Correction by a qualified contractor is recommended to reduce the potential for injury and prevent further deterioration of the affected area.

02.3 Walkways
Walkway Material Concrete
Overall Walkway Condition Functional
Cracking Observed? None
Settlement or Displacement Observed? None
Trip Hazards Present? No
Slip Hazard Present? No
02.4 Retaining Walls
Retaining walls present? No
02.5 Vegetation
Vegetation Contacting Structure? false, Encroaching Structure
Tree Limbs Overhanging Roof? Yes
Vegetation Obstructing Components? No
Tree Root Damage Observed? No
Dead or Deteriorated Trees Observed? No
Vegetation Limiting Inspection? No
02.D3 Medium Severity
Site & Grounds
Vegetation - Encroaching Structure

Vegetation was observed in contact with or encroaching upon the structure. Plant material in direct contact with a building can retain moisture against exterior surfaces and may provide a pathway for insects or pests to access the structure.

Trimming vegetation back from the structure is recommended to maintain clearance and reduce the potential for moisture-related deterioration at affected exterior surfaces. A qualified landscaping professional or general contractor can perform this work as conditions warrant.

Inspection photo Inspection photo Inspection photo Inspection photo
02.D4 Medium Severity
Site & Grounds
Vegetation - Tree Limbs Overhanging Roof

Tree limbs were observed overhanging the roof surface. Overhanging branches can deposit debris such as leaves and organic material onto the roof, which may contribute to moisture retention and accelerated deterioration of roofing materials. Branch contact or movement during wind events may also cause abrasion to the roof surface.

Trimming or removal of overhanging limbs by a qualified arborist or tree service professional is recommended to reduce the potential for debris accumulation and surface wear.

02.6 Irrigation
Irrigation system present? No
02.7 Fencing
Fencing Present? Yes
Fence Material Chain link
Overall Fence Condition Minor Wear
Fencing Contacts Structure? No
Fence Leaning or Movement Observed? Minor
Damaged or Missing Sections Observed? Minor
Gate Present? Yes
Gate Operational? Functional
Gate Self-Closing and Self-Latching? No
02.D5 Medium Severity
Site & Grounds
Fencing - Fence Movement

Movement was observed at the fence. This condition is commonly associated with post instability and may allow the fence to shift or lean further over time, reducing its effectiveness as a boundary or enclosure.

Evaluation and correction by a qualified fencing contractor is recommended as conditions warrant.

Inspector's Note
The fence has seen better days. It's not in terrible shape, but it is showing some wear and tear. Over time, you're going to need to replace portions of the fence - especially in areas in close proximity to trees or when vegetation is permitted to grow on the fence.
02.D6 Medium Severity
Site & Grounds
Fencing - Damaged or Missing Sections

Damaged or missing sections were observed at the fencing. This condition may reduce the effectiveness of the fence as a boundary barrier and can allow unintended access to the property. Left unaddressed, the affected areas may be subject to continued deterioration.

Evaluation and correction by a qualified fencing contractor is recommended to restore the fence to proper condition.

Inspection photo
02.D7 Low Severity
Site & Grounds
Gates - Missing Self-Closing/Self-Latching Feature

A gate was observed to be missing self-closing and/or self-latching hardware. Gates providing access to pool or yard enclosures are commonly expected to include self-closing and self-latching mechanisms to help ensure the gate returns to a secured position without manual intervention. Without these features, the gate may be left open unintentionally, reducing the effectiveness of the enclosure as a barrier.

Correction by a qualified contractor or fence professional is recommended to restore proper self-closing and self-latching function to the gate.

Inspector's Note
Always recommended, but not necessarily required on this property.
03.1 Shed
Shed Present? No
04.1 General Exterior
Building numbers visible and compliant? Yes
Exterior maintained by HOA? No
04.2 Wall Covering
Wall Covering Material(s) Vinyl siding
Cracking Observed? None
Deteriorated Materials Observed? No
Wall Covering in Contact with Ground? Yes - Soil/Dirt/Ground
Penetrations Properly Sealed? Yes
Paint/finish condition acceptable? Acceptable
04.D1 Medium Severity
Exterior
Wall Covering - Wall Covering Contacting Soil

Wall covering material at the home exterior was observed in direct contact with the soil. This condition is inconsistent with standard installation practices, as exterior wall coverings are intended to terminate above grade. When wall covering materials contact soil, they are exposed to sustained moisture, which may contribute to deterioration of the material over time. This condition may also increase the potential for moisture intrusion at the base of the wall assembly and can create conditions conducive to wood-destroying organism activity.

It is recommended that a qualified contractor evaluate the condition and correct as needed. Correction typically involves adjusting the grade or addressing the termination height of the wall covering to establish appropriate clearance above soil.

Inspection photo Inspection photo
04.3 Exterior Trim
Deteriorated Materials Observed? None
Trim in Contact with Ground or Hard Surfaces? None
Caulking / Sealant Condition Servicable
Protective Finish Condition Serviceable
04.4 Eaves, Soffits & Fascia
Soffit Deficiencies Observed? None
Fascia Deficiencies Observed? None
Soffit Vent Deficiencies Observed? None
Openings or Animal Entry Points Observed? None
04.5 Exterior Doors
Door Type(s) Present Hinged entry
Were All Exterior Doors Tested? Yes
Operational Issues Observed? None
Locking Hardware Deficiencies Observed? None
Weather Stripping Condition Serviceable
Door Seals Properly When Closed? Yes
Door or Frame Deficiencies Observed? None
Safety Glazing Present Where Required? Yes
04.6 Doorbell
Doorbell Present? No
04.7 Exterior Windows
Window type(s) Single-hung
Accessibility? Accessible
Window frame material Vinyl
Impact rated or hurricane protection? Non-Impact
Seals and caulking condition Serviceable
04.8 Pest Control Devices
Pest control devices observed? None Observed
04.9 Enclosed Porch
04.9.1 Porch/Patio Surface
Surface materialConcrete
Surface conditions observedServiceable
Evidence of ponding/drainage issues?No
Covered or uncovered?Covered — part of main roof
04.9.2 Screen Enclosure
Enclosure roof typePart of main roof structure
Fastener condition (screws, bolts, tie-downs)Serviceable
Spline conditionServiceable
05.1 Roof Structure
Inspection method Drone
Roof style Gable
Roof pitch Moderate (4:12-6:12)
Structural issues observed None
05.2 Roof Covering
Covering material Architectural shingles
Conditions observed Serviceable
Estimated remaining service life 10-15 years
05.3 Roof Flashing
Flashing conditions observed Serviceable
Kickout flashing present where required? Yes
05.4 Plumbing Vent Pipes
Vent pipe boot/flashing conditions Serviceable
05.5 Skylights
Skylights present? No
05.6 Gutters & Downspouts
Gutters present? No gutters installed
Gutters & Downspouts - Not Installed
The home does not have a gutter system, which is not unusual in Florida construction. Without gutters, roof ru...

The home does not have a gutter system, which is not unusual in Florida construction. Without gutters, roof runoff falls at the drip line, and the grading there must handle the concentrated water — erosion channels or splash-back staining on the lower walls are the signs it is not keeping up. If such signs develop, adding gutters with proper downspout extensions is the standard remedy.

06.1 Attic Access
Access location(s) Hallway ceiling
Hatch type(s) Scuttle hatch
Access condition Serviceable
06.D1 Medium Severity
Attic, Insulation & Ventilation
Hatch Insulation - Missing

No hatch insulation was observed where one would be expected. Insulation and ventilation work together to manage heat and moisture; a shortfall in either can raise energy costs and promote condensation-related problems. Recommend installation by a qualified professional.

Inspection photo
06.2 Structural Components
Framing type Trusses
Structural conditions observed Serviceable — no concerns
Active water penetration? No
Evidence of prior water penetration? No
Evidence of fire damage? No
Radiant barrier installed? Yes
Radiant Barrier - Overview
A radiant barrier was observed installed within the attic space of the home. Radiant barriers are reflective i...

A radiant barrier was observed installed within the attic space of the home. Radiant barriers are reflective insulation systems typically composed of a highly reflective material, most commonly aluminum foil, applied to one or both sides of a substrate such as kraft paper, plastic film, or oriented strand board (OSB). The primary function of a radiant barrier is to reduce radiant heat transfer, which occurs when heat energy travels from a warm surface to a cooler one without direct contact.

Radiant barriers are commonly installed in attic spaces, where they are positioned to reflect radiant heat from the roof decking before it can be absorbed by the attic floor insulation and transferred into the living space below. This type of system is generally associated with warmer climates where solar heat gain through the roof assembly is a significant factor in cooling loads, though it may be found in homes across a variety of regions.

Installation methods vary and may include stapling the material to the underside of the roof rafters, draping it over the attic floor insulation, or applying it directly to the roof sheathing. The effectiveness of a radiant barrier is generally dependent on the orientation of the reflective surface, the presence of an adjacent air space, and the overall attic ventilation conditions.

Radiant barriers are a passive system and do not require maintenance in the traditional sense, though the accumulation of dust on the reflective surface over time is a known characteristic that can affect performance. Radiant barriers are not a substitute for conventional thermal insulation and are typically intended to complement existing insulation rather than replace it.

06.3 Attic Insulation
Insulation type Blown cellulose
Approximate depth 6-9 inches
Insulation conditions Adequate and consistent
06.4 Attic Ventilation
Ventilation type(s) observed Ridge vent, Soffit vents
Mixed ventilation types observed? No
Soffit vents clear and unobstructed? Yes
Ridge vent present without soffit vents? No
Whole-House Fan Not present
07.1 General Foundation
Foundation type(s) present Slab on Grade
Method of inspection Visual
Exterior wall structure Wood framed (2x4)
Interior wall structure Wood framed (2x4)
Evidence of foundation movement? None Observed
Previous foundation repairs observed? None Observed
07.2 Slab Foundation
Visible slab cracking? None Observed
Evidence of heaving or settlement? No
08.1 Service Information
Service entrance type Overhead
Service entrance ampacity 150A
Service entrance voltage 120/240V
Service entrance feeder conductor Unable to confirm
08.D1 Medium Severity
Electrical
Overhead Conductors - Too Close to Trees

Overhead electrical conductors were observed in close proximity to tree branches at the time of inspection. Contact between tree limbs and overhead conductors presents a safety concern, as movement of branches during wind or storm events can result in damage to the conductors or service equipment.

It is recommended that a qualified arborist be engaged to trim or remove the encroaching tree branches, and that the serving utility company be contacted to evaluate conductor clearance and perform any necessary adjustments to the service lines.

08.2 Electric Meter
Meter present? Yes
Meter base condition Serviceable
Multiple meters present? No
08.3 Grounding & Bonding
Grounding electrode (ground rod) visible? Yes
Grounding electrode conductor (GEC) present? Yes
Ground rod connection condition Serviceable
08.4 Branch Circuit Wiring
Wiring type(s) observed NM-B (Romex)
08.5 Receptacles & GFCI
GFCI protection — Kitchen? Yes
GFCI Protection — Bathroom(s)? Yes
GFCI Protection — Exterior? Yes
GFCI Protection — Laundry? Unknown / Untested
Receptacle conditions Serviceable
08.D2 Medium Severity
Electrical
GFCI Protection (Laundry) - Unable to Verify

Unable to verify was observed at the GFCI protection (laundry). Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

08.6 Switches
Switch conditions Serviceable
08.7 Light Fixtures
Light fixture conditions Serviceable
08.8 Ceiling Fans
Ceiling fan conditions Serviceable
08.9 Smoke Detectors
Smoke detector conditions Serviceable
08.10 Carbon Monoxide Detectors
CO detectors required? No
08.11 Main Disconnect
08.11.1 Panel Information
Panel typeMeter-main combo
Panel locationExterior
Exterior/pole locationRight side
Panel manufacturerSiemens
Panel ampacity150A
Is this a sub-panel?Yes
08.11.2 Panel Condition
Dead front cover conditionServiceable
Panel conditions observedServiceable
Surge protection device (SPD) present?Yes
08.D3 High Severity
Electrical
SPD - Wired Direct to Main & Not On Breaker

The surge protective device (SPD) was observed to be wired directly to the main lugs of the electrical panel rather than connected through a dedicated circuit breaker. Without an overcurrent protective device on the SPD circuit, the wiring and device are not protected in the event of a fault condition.

A licensed electrician should be consulted to evaluate the installation and reconnect the SPD through an appropriately rated circuit breaker in accordance with the manufacturer's installation requirements and applicable electrical standards.

Inspection photo
08.11.3 Breakers & Wiring
Breaker conditionsServiceable
Wiring conditions inside panelServiceable
08.12 Distribution Panel
08.12.1 Panel Information
Panel typeDistribution Panel
Panel locationBedroom
Panel manufacturerSiemens
Panel ampacity150A
Is this a sub-panel?Yes
Sub-panel fed with 4 conductors?Yes
Neutrals and grounds separated in sub-panel?Yes
08.D4 Medium Severity
Electrical
Panel Location - In Bedroom/Closet

In bedroom/closet was observed at the panel location. Electrical conditions of this kind can contribute to shock or overheating concerns and tend to be inexpensive to correct when addressed early. Recommend correction by a licensed electrician.

08.12.2 Panel Condition
Dead front cover conditionServiceable
Panel conditions observedServiceable
08.12.3 Breakers & Wiring
Breaker conditionsServiceable
Wiring conditions inside panelServiceable
09.1 Ductwork
Ductwork type Flexible insulated
Ductwork location(s) Attic
Ductwork conditions Serviceable
Supply register conditions Serviceable
Return register conditions Serviceable
09.2 Mechanical Exhaust
Bathroom exhaust present? Yes
Bathroom fan type(s) Fan with light
Bathroom fan condition Serviceable
Bathroom exhaust termination To exterior — confirmed
Kitchen exhaust type Over-range microwave — recirculating
Kitchen exhaust operational? Yes
Kitchen exhaust condition Serviceable
Kitchen Exhaust - Recirculating vs. Ducted
Kitchen exhaust comes in two designs: ducted hoods carry cooking moisture, grease, and odors outdoors, while r...

Kitchen exhaust comes in two designs: ducted hoods carry cooking moisture, grease, and odors outdoors, while recirculating hoods filter the air through charcoal and return it to the room. Recirculating units are common and acceptable, but they remove no moisture and depend entirely on filter maintenance to do anything at all. Knowing which type the kitchen has sets maintenance expectations — and charcoal filters need periodic replacement to keep a recirculating hood useful.

09.3 AC
09.3.1 Split System Info
RefrigerantR-454B
SEER / SEER2 rating14.3
Cooling capacity2.0 Ton
Heating methodHeat pump
Heating capacity7.5 HSPF
09.3.2 Outdoor Unit
Year of Manufacture2025
Unit TypeHeat Pump
Unit level?Yes
Cabinet conditionServiceable
Refrigerant lines insulated?Yes
Refrigerant line conditionsServiceable
Disconnect present and within line of sight?Yes
Disconnect conditionServiceable
09.3.3 Indoor Unit
Data plate legible?Yes
Indoor unit locationCloset
Area surrounding unit clean and clear?Yes
Unit exterior conditionServiceable
Unusual noise?No
09.3.4 System Controls
Thermostat locationBedroom Hallway
Thermostat typeWiFi Thermostat, Smart Thermostat
Hard-wired or battery?Hard-Wired

The home is equipped with a smart or WiFi-connected thermostat. These devices are typically linked to the current owner’s online account, and the association does not transfer automatically with the sale. It is recommended to ask the seller to remove the device from their account so it can be registered to yours; otherwise, remote features and schedules may remain under the previous owner’s control.

09.3.5 Return & Filter
Filter typePleated
Filter conditionClean
Return air grille conditionServiceable
09.3.6 Condensate
Primary discharge locationExterior wall
Line conditionsServiceable
09.3.7 Temperatures
Cooling tested?Yes
Supply air temperature57 °F
Return air temperature76 °F
Heating tested?No — high ambient temperature

Heat pump heating is exercised only briefly — or not at all — during hot weather, because forcing a system to heat an already-hot home stresses the equipment and yields readings that mean little. This is standard practice, not an oversight. Verifying heating under suitable conditions, or through seller demonstration, is the recommended follow-up when the test could not be completed.

Limitations

Heating & Cooling Temperatures · #1
Heating - Not Tested (High Ambient Temperature)

The heating could not be fully evaluated because ambient conditions at the time of inspection made operation inadvisable, as running the equipment could damage it. The component’s condition under normal circumstances could not be fully verified.

Recommend evaluation under suitable conditions prior to closing where practical.

10.1 Main Water Shut-Off Valve
Location Water Meter
Valve type Ball valve
10.2 Water Pressure
Static water pressure reading 35 PSI
10.D1 Medium Severity
Plumbing
Water Pressure - Low (<40 PSI)

Low (<40 PSI) was observed at the water pressure. Conditions of this kind tend to progress if left unaddressed, and correction is generally most economical when performed early. Recommend further evaluation by a qualified professional.

10.3 Supply Piping
Supply pipe material(s) CPVC
Supply pipe conditions Serviceable
10.4 Water Treatment
Water treatment system present? None
10.5 DWV Piping
Drain pipe material(s) PVC
DWV conditions Serviceable
Main cleanout located? Yes
Main cleanout location Front Yard
Cleanout condition Serviceable
10.6 Hose Bibs
Hose bib conditions Serviceable
10.7 Water Heater
10.7.1 Water Heater Info
Water heater typeElectric tank
Fuel/power sourceElectric
Tank capacity40 gal
Year of manufacture2025
LocationCloset
10.7.2 Water Heater Condition
Condition observationsServiceable
10.7.3 Water Heater Performance
Hot water temperature at nearest fixtureBelow 120°F
Strong sulfur/rotten egg smell?No
10.D2 Medium Severity
Plumbing
Hot Water Temperature - Below Minimum (Below 120°F)

Below minimum (below 120°F) was observed at the hot water temperature. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend adjustment by a qualified professional.

Inspection photo
11.1 Flooring
Floor materials observed LVP/LVT
Floor conditions Serviceable
11.2 Interior Walls
Wall finish type Drywall
Wall conditions Serviceable
11.3 Ceilings
Ceiling conditions Serviceable
11.4 Interior Doors
Door conditions Serviceable
Interior keyed deadbolt observed? No
11.5 Interior Windows
Window conditions Serviceable, Hard to operate
11.D1 Medium Severity
Interior
Interior Windows - Hard to Operate

Hard to operate was observed at the interior windows. Beyond day-to-day function, openings in the building envelope also affect weather resistance and energy efficiency, so conditions here tend to have both convenience and moisture implications. Recommend adjustment by a qualified professional.

Inspection photo Inspection photo
11.6 Closets
Closet conditions Serviceable
12.1 Kitchen Sink
Faucet conditions Serviceable
Sink basin secure? Yes
Drain functional? Drains freely
Under-sink conditions Serviceable
12.2 Refrigerator
Refrigerator status Operational
Conditions Serviceable
Water line Yes — functional
12.3 Range / Oven / Cooktop
Fuel type Electric
Type Freestanding range
Anti-tip device installed? Yes
Condition Serviceable
12.4 Dishwasher
Dishwasher present? No
12.5 Built-In Microwave
Built-in microwave present? Yes — over range
Vent type Recirculating
12.6 Garbage Disposal
Disposal present? No
12.7 Countertops
Countertop material Laminate/Formica
Conditions Serviceable
12.8 Cabinets
Cabinet conditions Serviceable

Limitations

Kitchen Dishwasher · #1
Dishwasher - Not Present

The dishwasher was present at the time of inspection; however, this component falls outside the scope of a standard home inspection. It was noted for your awareness, but its condition, function, and safety were not evaluated.

If information about this component is desired, consultation with a qualified specialist in that field is recommended.

13.1 Toilet
Tank conditions Serviceable
Shutoff valve condition Serviceable
13.2 Bathroom Sink
Faucet conditions Serviceable
Drain functional? Drains freely
Under-sink conditions Serviceable
13.3 Tub / Shower
Configuration Tub/shower combo
Enclosure type Multi-piece fiberglass/acrylic
Drain functional? Drains freely
Enclosure conditions Serviceable
Hot & cold reversed? No
13.D1 Low Severity
Master Bathroom
Showerhead - Leaking

The showerhead was leaking at the time of inspection. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend repair by a qualified professional.

Inspection photo
13.4 Bathroom Ventilation
Ventilation type Exhaust fan
Fan condition Serviceable
13.5 Vanity & Cabinets
Vanity/cabinet conditions Serviceable
Mirror conditions Serviceable
14.1 Clothes Washer
Washer present? Yes — not tested
Supply valve conditions Serviceable
Supply hose type Braided stainless
Drain/standpipe conditions Serviceable
14.D1 Medium Severity
Laundry
GFCI Protection - Not Verified

Not verified was observed at the GFCI protection. Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

14.2 Clothes Dryer
Dryer present? Yes — tested
Power type 4-conductor 240V
Exhaust vent material Semi-rigid metal
Exhaust vent conditions Serviceable
Dryer conditions Serviceable
14.3 Cabinets and Shelving

Limitations

Laundry Clothes Washer · #1
Clothes Washer - Not Tested

The clothes washer was not operated or tested because the component could not be operated using normal controls at the time of inspection. Because operation was not verified, the component’s functional condition is unknown; a component that has not been run can conceal problems that only appear under use.

Recommend having the component demonstrated in normal operation, or evaluated by a qualified professional, prior to closing.

Inspection Summary

123 Sample Street · July 10, 2026
Group findings by
Highest-severity findings first
Findings organized by inspection section
Show findings:
High Severity 2 items
02.D1 High Severity
Site & Grounds — Driveway
Driveway - Moderate Cracking

Cracking and vertical displacement were observed in the concrete driveway slab at the time of inspection. Displacement of approximately 1 inch was noted at affected crack locations, with heaving of the slab surface present in multiple areas. The driveway surface is not severely deteriorated overall, but the displacement and cracking represent a notable departure from acceptable condition.

A qualified concrete or flatwork contractor should be consulted to evaluate the affected sections and recommend appropriate corrective action, which may include slab grinding, mudjacking, or panel replacement.

Inspection photo Inspection photo Inspection photo
08.D3 High Severity
Electrical — Main Disconnect › Panel Condition
SPD - Wired Direct to Main & Not On Breaker

The surge protective device (SPD) was observed to be wired directly to the main lugs of the electrical panel rather than connected through a dedicated circuit breaker. Without an overcurrent protective device on the SPD circuit, the wiring and device are not protected in the event of a fault condition.

A licensed electrician should be consulted to evaluate the installation and reconnect the SPD through an appropriately rated circuit breaker in accordance with the manufacturer's installation requirements and applicable electrical standards.

Inspection photo
Medium Severity 14 items
02.D2 Medium Severity
Site & Grounds — Driveway
Driveway - Trip Hazard

A trip hazard was observed at the driveway surface. The condition appears consistent with displacement or settlement of the paving material, resulting in an uneven surface edge or elevation change.

Trip hazards at driveways present a safety concern for occupants and visitors. The condition may worsen over time if contributing factors continue to affect the surface.

Correction by a qualified contractor is recommended to reduce the potential for injury and prevent further deterioration of the affected area.

02.D3 Medium Severity
Site & Grounds — Vegetation
Vegetation - Encroaching Structure

Vegetation was observed in contact with or encroaching upon the structure. Plant material in direct contact with a building can retain moisture against exterior surfaces and may provide a pathway for insects or pests to access the structure.

Trimming vegetation back from the structure is recommended to maintain clearance and reduce the potential for moisture-related deterioration at affected exterior surfaces. A qualified landscaping professional or general contractor can perform this work as conditions warrant.

Inspection photo Inspection photo Inspection photo Inspection photo
02.D4 Medium Severity
Site & Grounds — Vegetation
Vegetation - Tree Limbs Overhanging Roof

Tree limbs were observed overhanging the roof surface. Overhanging branches can deposit debris such as leaves and organic material onto the roof, which may contribute to moisture retention and accelerated deterioration of roofing materials. Branch contact or movement during wind events may also cause abrasion to the roof surface.

Trimming or removal of overhanging limbs by a qualified arborist or tree service professional is recommended to reduce the potential for debris accumulation and surface wear.

02.D5 Medium Severity
Site & Grounds — Fencing
Fencing - Fence Movement

Movement was observed at the fence. This condition is commonly associated with post instability and may allow the fence to shift or lean further over time, reducing its effectiveness as a boundary or enclosure.

Evaluation and correction by a qualified fencing contractor is recommended as conditions warrant.

Inspector's Note
The fence has seen better days. It's not in terrible shape, but it is showing some wear and tear. Over time, you're going to need to replace portions of the fence - especially in areas in close proximity to trees or when vegetation is permitted to grow on the fence.
02.D6 Medium Severity
Site & Grounds — Fencing
Fencing - Damaged or Missing Sections

Damaged or missing sections were observed at the fencing. This condition may reduce the effectiveness of the fence as a boundary barrier and can allow unintended access to the property. Left unaddressed, the affected areas may be subject to continued deterioration.

Evaluation and correction by a qualified fencing contractor is recommended to restore the fence to proper condition.

Inspection photo
04.D1 Medium Severity
Exterior — Wall Covering
Wall Covering - Wall Covering Contacting Soil

Wall covering material at the home exterior was observed in direct contact with the soil. This condition is inconsistent with standard installation practices, as exterior wall coverings are intended to terminate above grade. When wall covering materials contact soil, they are exposed to sustained moisture, which may contribute to deterioration of the material over time. This condition may also increase the potential for moisture intrusion at the base of the wall assembly and can create conditions conducive to wood-destroying organism activity.

It is recommended that a qualified contractor evaluate the condition and correct as needed. Correction typically involves adjusting the grade or addressing the termination height of the wall covering to establish appropriate clearance above soil.

Inspection photo Inspection photo
06.D1 Medium Severity
Attic, Insulation & Ventilation — Attic Access
Hatch Insulation - Missing

No hatch insulation was observed where one would be expected. Insulation and ventilation work together to manage heat and moisture; a shortfall in either can raise energy costs and promote condensation-related problems. Recommend installation by a qualified professional.

Inspection photo
08.D1 Medium Severity
Electrical — Service Information
Overhead Conductors - Too Close to Trees

Overhead electrical conductors were observed in close proximity to tree branches at the time of inspection. Contact between tree limbs and overhead conductors presents a safety concern, as movement of branches during wind or storm events can result in damage to the conductors or service equipment.

It is recommended that a qualified arborist be engaged to trim or remove the encroaching tree branches, and that the serving utility company be contacted to evaluate conductor clearance and perform any necessary adjustments to the service lines.

08.D2 Medium Severity
Electrical — Receptacles & GFCI
GFCI Protection (Laundry) - Unable to Verify

Unable to verify was observed at the GFCI protection (laundry). Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

08.D4 Medium Severity
Electrical — Distribution Panel › Panel Information
Panel Location - In Bedroom/Closet

In bedroom/closet was observed at the panel location. Electrical conditions of this kind can contribute to shock or overheating concerns and tend to be inexpensive to correct when addressed early. Recommend correction by a licensed electrician.

10.D1 Medium Severity
Plumbing — Water Pressure
Water Pressure - Low (<40 PSI)

Low (<40 PSI) was observed at the water pressure. Conditions of this kind tend to progress if left unaddressed, and correction is generally most economical when performed early. Recommend further evaluation by a qualified professional.

10.D2 Medium Severity
Plumbing — Water Heater › Water Heater Performance
Hot Water Temperature - Below Minimum (Below 120°F)

Below minimum (below 120°F) was observed at the hot water temperature. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend adjustment by a qualified professional.

Inspection photo
11.D1 Medium Severity
Interior — Interior Windows
Interior Windows - Hard to Operate

Hard to operate was observed at the interior windows. Beyond day-to-day function, openings in the building envelope also affect weather resistance and energy efficiency, so conditions here tend to have both convenience and moisture implications. Recommend adjustment by a qualified professional.

Inspection photo Inspection photo
14.D1 Medium Severity
Laundry — Clothes Washer
GFCI Protection - Not Verified

Not verified was observed at the GFCI protection. Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

Low Severity 2 items
02.D7 Low Severity
Site & Grounds — Fencing
Gates - Missing Self-Closing/Self-Latching Feature

A gate was observed to be missing self-closing and/or self-latching hardware. Gates providing access to pool or yard enclosures are commonly expected to include self-closing and self-latching mechanisms to help ensure the gate returns to a secured position without manual intervention. Without these features, the gate may be left open unintentionally, reducing the effectiveness of the enclosure as a barrier.

Correction by a qualified contractor or fence professional is recommended to restore proper self-closing and self-latching function to the gate.

Inspector's Note
Always recommended, but not necessarily required on this property.
13.D1 Low Severity
Master Bathroom — Tub / Shower
Showerhead - Leaking

The showerhead was leaking at the time of inspection. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend repair by a qualified professional.

Inspection photo
Site & Grounds 7 findings
02.D1 High Severity
Driveway
Driveway - Moderate Cracking

Cracking and vertical displacement were observed in the concrete driveway slab at the time of inspection. Displacement of approximately 1 inch was noted at affected crack locations, with heaving of the slab surface present in multiple areas. The driveway surface is not severely deteriorated overall, but the displacement and cracking represent a notable departure from acceptable condition.

A qualified concrete or flatwork contractor should be consulted to evaluate the affected sections and recommend appropriate corrective action, which may include slab grinding, mudjacking, or panel replacement.

Inspection photo Inspection photo Inspection photo
02.D2 Medium Severity
Driveway
Driveway - Trip Hazard

A trip hazard was observed at the driveway surface. The condition appears consistent with displacement or settlement of the paving material, resulting in an uneven surface edge or elevation change.

Trip hazards at driveways present a safety concern for occupants and visitors. The condition may worsen over time if contributing factors continue to affect the surface.

Correction by a qualified contractor is recommended to reduce the potential for injury and prevent further deterioration of the affected area.

02.D3 Medium Severity
Vegetation
Vegetation - Encroaching Structure

Vegetation was observed in contact with or encroaching upon the structure. Plant material in direct contact with a building can retain moisture against exterior surfaces and may provide a pathway for insects or pests to access the structure.

Trimming vegetation back from the structure is recommended to maintain clearance and reduce the potential for moisture-related deterioration at affected exterior surfaces. A qualified landscaping professional or general contractor can perform this work as conditions warrant.

Inspection photo Inspection photo Inspection photo Inspection photo
02.D4 Medium Severity
Vegetation
Vegetation - Tree Limbs Overhanging Roof

Tree limbs were observed overhanging the roof surface. Overhanging branches can deposit debris such as leaves and organic material onto the roof, which may contribute to moisture retention and accelerated deterioration of roofing materials. Branch contact or movement during wind events may also cause abrasion to the roof surface.

Trimming or removal of overhanging limbs by a qualified arborist or tree service professional is recommended to reduce the potential for debris accumulation and surface wear.

02.D5 Medium Severity
Fencing
Fencing - Fence Movement

Movement was observed at the fence. This condition is commonly associated with post instability and may allow the fence to shift or lean further over time, reducing its effectiveness as a boundary or enclosure.

Evaluation and correction by a qualified fencing contractor is recommended as conditions warrant.

Inspector's Note
The fence has seen better days. It's not in terrible shape, but it is showing some wear and tear. Over time, you're going to need to replace portions of the fence - especially in areas in close proximity to trees or when vegetation is permitted to grow on the fence.
02.D6 Medium Severity
Fencing
Fencing - Damaged or Missing Sections

Damaged or missing sections were observed at the fencing. This condition may reduce the effectiveness of the fence as a boundary barrier and can allow unintended access to the property. Left unaddressed, the affected areas may be subject to continued deterioration.

Evaluation and correction by a qualified fencing contractor is recommended to restore the fence to proper condition.

Inspection photo
02.D7 Low Severity
Fencing
Gates - Missing Self-Closing/Self-Latching Feature

A gate was observed to be missing self-closing and/or self-latching hardware. Gates providing access to pool or yard enclosures are commonly expected to include self-closing and self-latching mechanisms to help ensure the gate returns to a secured position without manual intervention. Without these features, the gate may be left open unintentionally, reducing the effectiveness of the enclosure as a barrier.

Correction by a qualified contractor or fence professional is recommended to restore proper self-closing and self-latching function to the gate.

Inspector's Note
Always recommended, but not necessarily required on this property.
Exterior 1 finding
04.D1 Medium Severity
Wall Covering
Wall Covering - Wall Covering Contacting Soil

Wall covering material at the home exterior was observed in direct contact with the soil. This condition is inconsistent with standard installation practices, as exterior wall coverings are intended to terminate above grade. When wall covering materials contact soil, they are exposed to sustained moisture, which may contribute to deterioration of the material over time. This condition may also increase the potential for moisture intrusion at the base of the wall assembly and can create conditions conducive to wood-destroying organism activity.

It is recommended that a qualified contractor evaluate the condition and correct as needed. Correction typically involves adjusting the grade or addressing the termination height of the wall covering to establish appropriate clearance above soil.

Inspection photo Inspection photo
Attic, Insulation & Ventilation 1 finding
06.D1 Medium Severity
Attic Access
Hatch Insulation - Missing

No hatch insulation was observed where one would be expected. Insulation and ventilation work together to manage heat and moisture; a shortfall in either can raise energy costs and promote condensation-related problems. Recommend installation by a qualified professional.

Inspection photo
Electrical 4 findings
08.D3 High Severity
Main Disconnect › Panel Condition
SPD - Wired Direct to Main & Not On Breaker

The surge protective device (SPD) was observed to be wired directly to the main lugs of the electrical panel rather than connected through a dedicated circuit breaker. Without an overcurrent protective device on the SPD circuit, the wiring and device are not protected in the event of a fault condition.

A licensed electrician should be consulted to evaluate the installation and reconnect the SPD through an appropriately rated circuit breaker in accordance with the manufacturer's installation requirements and applicable electrical standards.

Inspection photo
08.D1 Medium Severity
Service Information
Overhead Conductors - Too Close to Trees

Overhead electrical conductors were observed in close proximity to tree branches at the time of inspection. Contact between tree limbs and overhead conductors presents a safety concern, as movement of branches during wind or storm events can result in damage to the conductors or service equipment.

It is recommended that a qualified arborist be engaged to trim or remove the encroaching tree branches, and that the serving utility company be contacted to evaluate conductor clearance and perform any necessary adjustments to the service lines.

08.D2 Medium Severity
Receptacles & GFCI
GFCI Protection (Laundry) - Unable to Verify

Unable to verify was observed at the GFCI protection (laundry). Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

08.D4 Medium Severity
Distribution Panel › Panel Information
Panel Location - In Bedroom/Closet

In bedroom/closet was observed at the panel location. Electrical conditions of this kind can contribute to shock or overheating concerns and tend to be inexpensive to correct when addressed early. Recommend correction by a licensed electrician.

Plumbing 2 findings
10.D1 Medium Severity
Water Pressure
Water Pressure - Low (<40 PSI)

Low (<40 PSI) was observed at the water pressure. Conditions of this kind tend to progress if left unaddressed, and correction is generally most economical when performed early. Recommend further evaluation by a qualified professional.

10.D2 Medium Severity
Water Heater › Water Heater Performance
Hot Water Temperature - Below Minimum (Below 120°F)

Below minimum (below 120°F) was observed at the hot water temperature. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend adjustment by a qualified professional.

Inspection photo
Interior 1 finding
11.D1 Medium Severity
Interior Windows
Interior Windows - Hard to Operate

Hard to operate was observed at the interior windows. Beyond day-to-day function, openings in the building envelope also affect weather resistance and energy efficiency, so conditions here tend to have both convenience and moisture implications. Recommend adjustment by a qualified professional.

Inspection photo Inspection photo
Master Bathroom 1 finding
13.D1 Low Severity
Tub / Shower
Showerhead - Leaking

The showerhead was leaking at the time of inspection. Left unaddressed, plumbing conditions of this kind can allow moisture to reach surrounding materials, and moisture-related damage typically grows more costly over time. Recommend repair by a qualified professional.

Inspection photo
Laundry 1 finding
14.D1 Medium Severity
Clothes Washer
GFCI Protection - Not Verified

Not verified was observed at the GFCI protection. Because this component serves a protective function, a condition affecting it means the protection it provides may not be available when needed. Recommend further evaluation by a qualified professional.

Checklist

123 Sample Street · July 10, 2026
Download PDF
Track completed repairs by checking items off as they're addressed. This checklist is for your personal use only and is not saved or stored.
High Severity 2 items
Driveway - Moderate Cracking
Site & Grounds — Driveway · Service / Maintain
High Severity
SPD - Wired Direct to Main & Not On Breaker
Electrical — Main Disconnect › Panel Condition
High Severity
Medium Severity 14 items
Driveway - Trip Hazard
Site & Grounds — Driveway · Service / Maintain
Medium Severity
Vegetation - Encroaching Structure
Site & Grounds — Vegetation · Service / Maintain
Medium Severity
Vegetation - Tree Limbs Overhanging Roof
Site & Grounds — Vegetation
Medium Severity
Fencing - Fence Movement
Site & Grounds — Fencing · Service / Maintain
Medium Severity
Fencing - Damaged or Missing Sections
Site & Grounds — Fencing · Service / Maintain
Medium Severity
Wall Covering - Wall Covering Contacting Soil
Exterior — Wall Covering · Improve Grading
Medium Severity
Hatch Insulation - Missing
Attic, Insulation & Ventilation — Attic Access · Install
Medium Severity
Overhead Conductors - Too Close to Trees
Electrical — Service Information
Medium Severity
GFCI Protection (Laundry) - Unable to Verify
Electrical — Receptacles & GFCI · Further Evaluation Recommended
Medium Severity
Panel Location - In Bedroom/Closet
Electrical — Distribution Panel › Panel Information · Consult Licensed Electrician
Medium Severity
Water Pressure - Low (<40 PSI)
Plumbing — Water Pressure · Further Evaluation Recommended
Medium Severity
Hot Water Temperature - Below Minimum (Below 120°F)
Plumbing — Water Heater › Water Heater Performance · Adjust
Medium Severity
Interior Windows - Hard to Operate
Interior — Interior Windows · Adjust
Medium Severity
GFCI Protection - Not Verified
Laundry — Clothes Washer · Further Evaluation Recommended
Medium Severity
Low Severity 2 items
Gates - Missing Self-Closing/Self-Latching Feature
Site & Grounds — Fencing · Install
Low Severity
Showerhead - Leaking
Master Bathroom — Tub / Shower · Repair
Low Severity